Williamson
Boilers
|
| GWA Gas-Fired Water Boiler GWI Gas-Fired Water Boiler
GWS Gas-Fired Water Boiler
GSA Gas-Fired Steam Boiler
OWB Oil-Fired Water Boiler
OWT Oil-Fired Water Boiler
OSB/T Oil-Fired Steam Boiler |
|
GWA Gas-Fired Water Boiler
52,000 to 245,000 Btuh Input
Natural or PropaneDimensions and Specifications
|
Construction
Atmospheric (chimney) venting
Factory Packaged
Factory Tested
Easy
service
+ One-piece access door
+ All controls in easy reach
High
efficiency
+ Flue baffles
+ Stainless steel burners
+ Automatic vent damper
Cast
iron sections
Insulated heavy-gauge steel jacket
Limited lifetime warranty |
Equipment
Cast
iron sections with built-in air separator
Vertical draft hood
Electrical junction box
24-VAC combination gas valve
Combination relay receptacle and 40VA
transformer and plug-in circulator relay
Taco 007 circulator
High temperature limit control
30 PSIG ASME relief valve
Combination pressure/temperature gauge
Standing Pilot Models
Constant-burning pilot system, thermally
supervised
Intermittent Pilot Models
Spark-ignited (intermittent) pilot system
Electronic ignition/flame supervisory control |
GWI Gas-Fired Water Boiler
47,500 to 190,000 Btuh
Input
Natural or Propane
Dimensions
and Specifications
|
Construction
Induced-draft combustion system allows
sidewall or chimney venting
Factory
Packaged
Compact Design
Factory Tested
Easy
to service
+ One-piece access door
+ All controls in easy reach
+ Color-coded wiring
High
Efficiency
+ AFUEs to 83.3%
+ Spark-ignited pilot with electronic control
Cast
iron sections with built-in air separator
Insulated
heavy-gauge steel jacket
Limited lifetime warranty |
Equipment
Insulated extended steel jacket
Induced-draft blower assembly
Air Pressure switch
Stainless steel burners
Electrical junction box
24-VAC combination gas valve
Combination relay receptacle and 40VA
transformer and plug-in circulator relay
Taco 007 circulator
High temperature limit control
30 PSIG ASME relief valve
Combination pressure/temperature gauge
Spark-ignited (intermittent) pilot system
Electronic ignition/flame supervisory
control |
GWS Gas-Fired Water Boiler
63,000 to 158,000 Btuh
Input
Natural or Propane Dimensions and Specifications
|
Construction
Sealed combustion option allows
use of outside combustion air
Factory
Packaged
Compact Design
Factory Tested
Easy
to service
+ One-piece access door
+ Plug-in wiring
+ Control module with diagnostic lights
High
Efficiency
+AFUEs to 85.3%
+Spark-ignited pilot with electronic control
Cast
iron sections with built-in air separator
Insulated
heavy-gauge steel jacket
Limited lifetime warranty |
Equipment
Insulated extended steel jacket
Induced-draft blower assembly
Air Pressure switch
Stainless steel burners
Electrical junction box
24-VAC combination gas valve
40VA control transformer
Plug-in wiring
Taco 007 circulator
High temperature limit control
30 PSIG ASME relief valve
Combination pressure/temperature gauge
Spark-ignited (intermittent) pilot system
Electronic ignition/flame supervisory
control |
GSA Gas-Fired Steam Boiler
75,000 to 250,000 Btuh
Input
Natural or Propane
|
Construction
Atmospheric (chimney) venting
Factory Packaged
Factory Tested
Easy
service
+ One-piece access door
+ All controls in easy reach
High
efficiency
+ Generous heating surface
+ Automatic vent damper
Cast
iron sections
Rugged construction for long life
+ Integral cast iron legs
+ Integral draft diverter
+ Insulated heavy-gauge steel jacket
+ Heavy-gauge aluminized steel flue collector
10-Year warranty on boiler sections
|
Equipment
Factory
assembled cast iron sections
24-VAC combination gas valve
Gauge glass and guard assembly
Pressure gauge and siphon assembly
Pressure limit control
Probe low water cutoff
High temperature limit control
Automatic vent damper
15 PSIG ASME relief valve
Constant-burning pilot system,
thermally-supervised
Drain valve |
OWB Oil-Fired Water Boiler
0.75 to 2.00 GPH Input
Dimensions
and Specifications
|
Construction
Factory Packaged
Factory Tested
Easy
service
+ Swing-away burner door
+ Low draft loss
+ Top access cleanout cover
+ Plug-in wiring harness
High
efficiency oil burner
+ Flame retention head design
+ Solenoid valve
+ PSC motor
+ Solid state ignitor
Rear
flue outlet
Cast iron sections with built-in air separator
Insulated heavy-gauge steel jacket
Limited lifetime warranty |
Equipment
Factory-assembled cast iron section assembly,
including aluminized steel flue collector,
swing-away burner mounting door, with refractory
blanket and recessed target wall in combustion
chamber.
Taco 007 circulator
High efficiency flame-retention oil burner
(Beckett AFG, Weil-McLain QB, or
Carlin EZ)
High limit control with circulator relay
Built-in air separator
Combination pressure/temperature gauge
30 PSIG ASME relief valve
Drain valve
Barometric damper
Optional
Two-stage oil
burner fuel unit
|
OWT Oil-Fired Water Boiler
0.75 to 2.00 GPH Input
With tankless heater Dimensions and Specifications
|
Construction
Factory Packaged
Factory Tested
Easy
service
+ Swing-away burner door
+ Low draft loss
+ Top access cleanout cover
+ Plug-in wiring harness
High
efficiency oil burner
+ Flame retention head design
+ Solenoid valve
+ PSC motor
+ Solid state ignitor
Rear
flue outlet
Cast iron sections with built-in air separator
Insulated heavy-gauge steel jacket
Limited lifetime warranty
|
Equipment
Factory-assembled cast iron section assembly,
including aluminized steel flue collector,
swing-away burner mounting door, with refractory
blanket and recessed target wall in combustion
chamber.
Taco 007 circulator
High efficiency flame-retention oil burner
(Beckett AFG, Weil-McLain QB, or
Carlin EZ)
High limit control with circulator relay
Built-in air separator
Combination pressure/temperature gauge
30 PSIG ASME relief valve
Drain valve
Barometric damper
Tankless heater
Optional
Two-stage oil
burner fuel unit |
OSB/T Oil-Fired Steam Boiler
1.00 to 2.00 GPH Input
Optional tankless heater Dimensions and Specifications
|
Construction
Factory Packaged
Factory Tested
Easy
service
+ Swing-away burner door
+ Low draft loss
+ Top access cleanout cover
+ Plug-in wiring harness
High
efficiency oil burner
+ Flame retention head design
+ Solenoid valve
+ PSC motor
+ Solid state ignitor
Rear
flue outlet
Cast iron sections with built-in air separator
Insulated heavy-gauge steel jacket
Limited lifetime warranty
|
Equipment
Factory-assembled cast iron section assembly,
including aluminized steel flue collector,
swing-away burner mounting door, refractory
blanket and recessed target wall in combustion
chamber.
Flame-retention oil burner
(Beckett AFG, Weil-McLain QB, or
Carlin EZ)
High limit pressure control
Probe low water cutoff
Pressure gauge
Siphon
Gauge glass, gauge cocks and guards
15 PSIG ASME relief valve
Drain valve
Barometric damper
Optional
Two-stage oil
burner fuel unit
Tankless heater, shipped in separate carton
|
|